EVO-RX

Ductless air handling units

Certificates
PL-EN 1886:2008
ISO 13053
ISO 9001
ISO 14001
Eurovent
ETL
CE

EVO-RX components

1
2
3
4
5
6
7
8
1
Framework
  • High corrosion resistant galvanized steel profiles (insulation version 50), plastic corners
2
Panels
  • Unique Thermal Brake panels made of galvanized metal sheet with high corrosion resistance coating 0,7mm thick
  • Panel thickness of 50mm filled with non-combustible mineral wool – A1 class fire protection
  • Fixed panels riveted to the framework and insulated with sealant
  • Access panels fixed by clamps, with pull handles
  • Sealing access panels-construction by profile gasket. The housing is divided into outdoor and indoor module
3
Base frame
  • Not included. The AHU is installed on construction
4
Drain pan
  • Made of stainless steel, triple sloped, insulated with rubber mat. Drainage pipe made of plastic pipe, led out to the side through the AHU’s profile beyond the outline.
  • Universal trap for under and overpressure in the place of operation
5
Guide vanes
  • Made of high corrosion resistant galvanized steel or stainless steel
6
Air dampers
  • Standard aluminium construction. The mechanism hidden in the double profile, separated from external factors. The dampers are fitted with components of the Intake / Outtake
7
Connections
  • Not included
8
Additional equipment
  • “Dumbo” terminals for pressure switch hoses connection, installed on the AHU’s fixed casing. Intake / Outtake roof

Functions performed

Close
Primary filter
PF
Functions and application

application

An air-conditioning and ventilation systems with standard purity requirements as preliminary filter

An air-conditioning and ventilation systems with strict purity requirements as preliminary and secondary filter

An air-conditioning and ventilation systems with standard or strict purity requirements as the final filtration stage

Catching fat particles and heavy pollutants (metal filter)

type

Metal plate filter

G2 - ISO COARSE

Plate filter:

G4 - ISO COARSE

M5 - ISOePM10-70%

Minipleat filter:

M5 - ISOePM10-70%

F7 - ISOePM2,5-60%

F9 - ISOePM1-80%

Bag filter:

M5 - ISOePM10-50%

F7 - ISOePM2,5-65%

F9 - ISOePM1-70%/80%

Construction

metal filter

Multi layer mesh covered on both sides with galvanized steel mesh mounted in 50mm thick frame

Filteration mesh made of galvanized steel

plate filter

Filter textile covered on both sides with galvanized steel mesh

Mounted in 50mm thick frame

Filter textile made of synthetic polyester filaments

minipleat filter

Mini pleat filter packages with hot melt separators

Mounted in 50/100 mm thick frame

Glass or synthetic fabric refill (100% polypropylene)

bag filter

Pockets sewn and placed on wire truss; bags lenght 300/500mm

Mounted in 25mm thick frame; eccentric crimping

Three-layer synthetic non-woven, polypropylene, using micro fibres

Parameters

 (acc. EN 13053+A1:2011 and EN 779:2012)

metal filter

Filtration grade Am: 80%

End pressure drop Δp: 120Pa

Maximum air velocity v: 4,2m/s

Maximum working temperature: 300°C

plate filter

Filtration grade Am: 82% ÷ 92%

End pressure drop: Δp: 150Pa ÷ 200Pa

Maximum air velocity v: 4,2m/s

Maximum working temperature: 90 ÷ 100°C

minipleat filter

Filtration grade Am: 95% ÷ 99%

Final pressure drop: Δp = 150Pa ÷ 200Pa

Maximum air velocity v: 4,2m/s

Maximum working temperature: 80°C

bag filter

Filtration grade Am: 95% ÷ 99%

Final pressure drop: Δp = 200Pa ÷ 300Pa

Maximum air velocity v: 3,7 ÷ 4,6m/s

Maximum working temperature: 90 ÷ 100°C 

Close
Water heating coil
WH
Functions and application

Application:

  • Heating of supply air in air conditioning and ventilation systems
  • Heating of process air in industry-grade air conditioning and ventilation systems
Construction
  • Copper tubes; aluminium fins (standard) additionaly protected by epoxy coating (EVO-P)
  • Galvanized metal sheet or stainless (EVO-P) frame
  • Mainfolds and connectors made of copper or steel respectively
  • Exchanger connection stub pipes fitted with drain and vent
  • Number of rows: 1 ÷ 6
  • Distance between fins: 1,8 / 2,0 / 2,5mm
  • Fin thickness: 0,1mm
  • Tube wall thickness: 0,37mm
  • Tube diameter: 3/8” ÷ 5/8”

 

Exchanger medium connection:

  • Connection stub pipes are on the service side of the unit.
  • Medium connection from top or bottom exchanger in order to maintain medium counter flow direction according to the air flow direction.
Parameters

(Conformance to standards: EN 308, EN 1216, EN 13053)

  • Max. medium temperature: 120°C
  • Max. medium working pressure: 1,6MPa = 16bar (tested 21 bar)
  • Max. permitted air flow speed: v = 4,6m/s
  • Max. glycol content: 50%
  • Min./max. temperature of the air: - 40/60°C
  • Protection: permissible minimum temperature of air downstream heat exchanger is monitored by freezing protection thermostat (optional)
  • Heating capacity, pressure losses, etc. available in KAD software
Close
Water cooling coil
WC
Functions and application
  • Cooling of supply air in air conditioning and ventilation systems
  • Cooling of process air in industry-grade air conditioning and ventilation systems
  • Dehumidyfing of process air in industry-grade air conditioning and ventilation systems
Construction
  • Copper tubes; aluminium fins (standard) additionaly protected by epoxy coating (EVO-P)
  • Galvanized metal sheet or stainless (EVO-P) frame
  • Mainfolds and connectors made of copper or steel respectively
  • Exchanger connection stub pipes fitted with drain and vent
  • Number of rows R: 2÷12
  • Distance between fins: 2,5 mm
  • Fin thickness: 0,1mm
  • Tube wall thickness: 0,37 mm
  • Tube diameter: 3/8” ÷ 5/8”
  • Droplet eliminator mounted downstream after the cooler
  • Triple sloped drain pan made of stainless steel, buil-in AHU floor
  • Drain pan equipped with polypropylene ball siphon
Parameters

(Conformance to standards: EN 308, EN 1216, EN 13053)

 

  • Min. temp. of the medium: +2°C*
  • Max. working pressure of the medium: 1,6MPa = 16bar (tested 21 bar)
  • Max. glycol content: 50%
  • Max. permitted air velocity: v = 4,0 m/s
  • Cooling capacity, pressure drop, etc. available in KAD
Close
Direct expansion cooling coil
DX
Functions and application
  • Cooling of supply air in air conditioning and ventilation systems
  • Cooling of process air in industry-grade air conditioning and ventilation systems
  • Dehumidyfing of process air in industry-grade air conditioning and ventilation systems
Construction
  • Copper tubes; aluminium fins (standard) additionaly protected by epoxy coating (EVO-P)
  • Single (100%) or double section heat exchanger
  • Galvanized metal sheet or stainless (EVO-P) frame
  • Number of cooler rows R: 2÷10
  • Distance between fins: 2,5mm
  • Fin thickness: 0,1mm
  • Tube wall thickness: 0,37mm
  • Tube diameter: 3/8” ÷ 5/8”
  • Droplet eliminator mounted downstream after the cooler
  • Triple sloped drain pan made of stainless steel, buil-in AHU floor
  • Drain pan equipped with polypropylene ball siphon

 

Exchanger medium connection

  • Connection stub pipes are on the service side of the unit.
  • Medium connection from top of the exchanger independent of air flow direction
Parameters

(Conformance to standards: EN 308, EN 1216, EN 13053)

 

  • Min. evaporating temperature of cooling medium evaporation: +3°C*
  • Max. working pressure of the medium up to 2,8MPa = 28bar (tested 32bar)
  • Max. permitted air velocity v = 4,1m/s
  • You can select an exchanger suitable for wide range of refrigerants: R134a, R407c, R410a…
  • Cooling capacity, pressure drops, etc. available in KAD selection software
Close
Fan set
VF
Functions and application

Application

  • Low and medium pressure ventilation and air-conditioning systems with overall pressures up to 2 000Pa
  • Medium pressure ventilation and air-conditioning systems with overall pressures up to 3 000Pa (marine industry EVO-M)
  • Applied as a single or multi fan (up to 6 fans sets) solution depends on AHU size and pressure drop

 

Type

  • AC fan set: SWSI centrifugal fan without casing, one-way suction, PLUG type, with backward curved blades
  • EC fan set: SWSI centrifugal fan without casing, one-way suction, PLUG type, with backward curved blades
  • AC fan set (EVO-M marine execution): DWDI centrifugal fan with casing, two-way suction, with backward curved blade
Construction

AC fan set

  • Fan and motor set on common frame, insulated from unit structure by rubber shock absorbers
  • Direct drive – impeller mounted on motor shaft
  • TEFC single speed motors conforming to IEC standard
  • Suitable for supplying by VFD (variable frequency drive) – optional accessory

 

EC fan set

  • Fan and motor set on common frame assemled directly to AHU diaphragm
  • Direct drive – impeller mounted on motor shaft
  • Single speed motors conforming to IEC standard
  • Built- in speed amd monitoring controller

 

AC fan set (EVO-M marine execution)

  • Fan & motor set on common frame, insulated from unit structure by rubber shock absorbers belt drive
  • TEFC marine executiony single speed or two speed motors conforming to IEC standard
  • The motor assambled on tension support
  • Suitable for supplying by VFD (variable frequency drive) – optional accessory
  • The construction and fan epoxy coated protected

 

Parameters

AC fan set

  • Rated voltage: 3x400V / 50Hz
  • Rated power: 0,75 kW ÷ 15 kW
  • Protection type: PTC
  • Motor winding insulation class: F (matching with frequency converter)
  • Bearing lifecycle: L10 = 20000h / L50 = 100000h
  • Protection class: IP55
  • Efficiency class: IE2 / IE3
  • VFD output frequency range: 10 -100 Hz
  • Min. / max working temperature: -30°C ÷ 55°C

 

EC fan set

  • Rated voltage: 1x230V / 3x400V / 50Hz
  • Rated power: 0,5 kW ÷ 11,9 kW
  • Motor winding insulation class: B/F respectively (matching with EC controller)
  • Bearing lifecycle: L10 = 40000h / L50 = 200000h
  • Protection class: IP54 / IP55 respectively
  • Efficiency class: above IE3
  • A corresponding sensor with standard analogue output (0 ÷ 10 V or 4 ÷ 20 mA)
  • The open protocol standard RS485 MODBUS-RTU
  • Min. / max working temperature: -25°C ÷ 60°C

 

AC fan set (EVO-M marine execution)

  • Rated voltage: 1x230 / 3x400V / 3x440 / 3x690 - 50/60Hz
  • Rated power: 0,75 kW ÷ 22,5 kW
  • Protection type: PTC
  • Motor winding insulation class: F (mating with frequency converter)
  • Bearing lifecycle: L10 = 20000h / L50 = 100000h
  • Protection class: IP55
  • Efficiency class: IE2
  • VFD output frequency range: 10 ÷ 100 Hz
  • Min. / max working temperature: -30°C ÷ 55°C

 

POWER COEFFICIENT DEPENDS ON WORKING TEMPERATURE

Max. ambient temp. °C

30

35

40

45

50

55

60

P/PN %

105

102

100

97

93

87

82

Close
Counterflow plate heat exchanger
CPR
Functions and application
  • Indirect energy recovery from exhaust air and transfer of such energy to supply air, without possibility of humidity recovery
  • Complete separation of supply air from exhaust air streams
  • Used in combined supply and exhaust units in vertical and horizonatal AHU execution
  • Passive House ready
Construction

Counterflow plate heat exchanger

  • The block is made of aluminium plates (EVO-S / EVO-H) additionaly epoxy coated (EVO-P) with separated supply and exhaust air streams flowing between them
  • 100% by-pass with installed air damper allows to “avoid” the exchanger, that is:
    - Accordingly to decrease or “to switch off” energy recovery
    - Protect the exchanger against freezing
  • Droplet separator with triple sloped drain pan built-in AHU floor
  • Drain pan equipped with polypropylene ball siphon
Parameters

(Conformance to standards: EN 308, EN 13053)

 

Counterflow plate heat exchanger

  • Max. air volume flow: 20 000m3/h
  • Efficiency: up to 92%
  • Heat-exchanger tightness for rated working parameters (250Pa) 99,5%
  • Max. air velocity: 4,5m/s
  • Max. pressure drop: 400Pa
  • Permitted pressure difference: 800Pa
  • Min. / max. working temperature: -40 ÷ 80°C
PF
Primary filter
WH
Water heating coil
WC
Water cooling coil
DX
Direct expansion cooling coil
VF
Fan set
CPR
Counterflow plate heat exchanger

Application

Offices
Shops & stores
Malls
Restaurants
Warehouses
Public facilities

Basic configuration

Size

Air capacity

External unit

Internal unit

min.

max

B

H

L

Weight

B1

H1*

H2*

L1

øD

Weight

 

m3/h

m3/h

mm

mm

mm

kg

mm

mm

mm

mm

mm

kg

EVO-RX 0500

3750

5750

1300

1950

2560

165

950

1650

510

950

630

534

EVO-RX 0800

6000

9200

1650

2360

2970

196

1050

1650

510

1050

800

835

 

Files to download

Klimor Air Designer

The web-based software offers a quick selection of products according to the specific design requirements. The software provides users with all necessary technical information.
Go to the configurator