Our products worldwide
Austria, Azerbaijan, Belarus, Belgium, Bulgaria, Canada, Estonia, Finland, France, Georgia, Germany, Hungary, Kazakhstan, Latvia, Lithuania, Moldova, Netherlands, Norway, Portugal, Romania, Slovakia, Spain, Sweden, Ukraine, United Kingdom, USA
Products Compact air handling unitsEVO-T CompactDiscover Klimor EVO technology

EVO-T Compact

Suspended compact air handling unit

Certificates
PL-EN 1886:2008
ISO 13053
ISO 9001
ISO 14001
Eurovent
ETL
CE

EVO-T Compact components

1
2
3
4
5
6
7
8
1
Framework
  • Frameless technology
2
Casing
  • Made of 0.7 mm galvanized steel sheet with a high corrosion resistance coating bent into a U-shape
  • Wall thickness 25 mm
  • Non-flammable mineral wool filling of class A2-S1
  • Inspection covers, equipped with handles, fixed to the butterfly screw casing
  • Seal cover-casing with a flat seal
3
Base frame
  • Without frame.
  • Device designed to hang on handles.
  • Handles also used to connect sections
4
Drain pan
  • Made of stainless steel, two-way sloped, insulated with rubber mat.
  • Drainage pipe made of stainless steel pipe, led out to the side through the AHU’s wall beyond the outline.
  • Universal trap for under and overpressure in the place of operation. It is not required to elevate the frame for the pressure of 600Pa.
5
Guide vanes
  • Made of high corrosion resistant galvanized steel or stainless steel.
6
Air dampers
  • Standard aluminium construction. The mechanism hidden in the double profile, separated from external factors.
7
Connections
  • Standard flexible connectors with connectable duct profile.
8
Additional equipment
  • “Dumbo” terminals for pressure switch hoses connection, installed on the AHU’s fixed casing
  • Lighting – low voltage led technology – option
  • Porthole – option

Functions performed

Close
Water heating coil
WH
Functions and application

Application:

  • Heating of supply air in air conditioning and ventilation systems
  • Heating of process air in industry-grade air conditioning and ventilation systems
Construction
  • Copper tubes; aluminium fins (standard) additionaly protected by epoxy coating (EVO-P)
  • Galvanized metal sheet or stainless (EVO-P) frame
  • Mainfolds and connectors made of copper or steel respectively
  • Exchanger connection stub pipes fitted with drain and vent
  • Number of rows: 1 ÷ 6
  • Distance between fins: 1,8 / 2,0 / 2,5mm
  • Fin thickness: 0,1mm
  • Tube wall thickness: 0,37mm
  • Tube diameter: 3/8” ÷ 5/8”

 

Exchanger medium connection:

  • Connection stub pipes are on the service side of the unit.
  • Medium connection from top or bottom exchanger in order to maintain medium counter flow direction according to the air flow direction.
Parameters

(Conformance to standards: EN 308, EN 1216, EN 13053)

  • Max. medium temperature: 120°C
  • Max. medium working pressure: 1,6MPa = 16bar (tested 21 bar)
  • Max. permitted air flow speed: v = 4,6m/s
  • Max. glycol content: 50%
  • Min./max. temperature of the air: - 40/60°C
  • Protection: permissible minimum temperature of air downstream heat exchanger is monitored by freezing protection thermostat (optional)
  • Heating capacity, pressure losses, etc. available in KAD software
Close
Water cooling coil
WC
Functions and application
  • Cooling of supply air in air conditioning and ventilation systems
  • Cooling of process air in industry-grade air conditioning and ventilation systems
  • Dehumidyfing of process air in industry-grade air conditioning and ventilation systems
Construction
  • Copper tubes; aluminium fins (standard) additionaly protected by epoxy coating (EVO-P)
  • Galvanized metal sheet or stainless (EVO-P) frame
  • Mainfolds and connectors made of copper or steel respectively
  • Exchanger connection stub pipes fitted with drain and vent
  • Number of rows R: 2÷12
  • Distance between fins: 2,5 mm
  • Fin thickness: 0,1mm
  • Tube wall thickness: 0,37 mm
  • Tube diameter: 3/8” ÷ 5/8”
  • Droplet eliminator mounted downstream after the cooler
  • Triple sloped drain pan made of stainless steel, buil-in AHU floor
  • Drain pan equipped with polypropylene ball siphon
Parameters

(Conformance to standards: EN 308, EN 1216, EN 13053)

 

  • Min. temp. of the medium: +2°C*
  • Max. working pressure of the medium: 1,6MPa = 16bar (tested 21 bar)
  • Max. glycol content: 50%
  • Max. permitted air velocity: v = 4,0 m/s
  • Cooling capacity, pressure drop, etc. available in KAD
Close
Electrical heater
EH
Functions and application
  • Heating of supply air in air conditioning and ventilation systems
  • Heating of process air in industry-grade air conditioning and ventilation systems
  • Preheating air in air hanglin units
Construction
  • Single or multi-stage heating components
  • Radiator heaters combined in groups
  • Casing: framework made of galvanized metal sheet
  • Connection to terminal strip
  • Overheating protection thermostat (standard)

 

Exchanger connection

  • Connecting the wires to the terminal strip of the heater are on the service side of the unit
Parameters
  • Rated voltage: 3 x 400V
  • Min. / max. rating capacity: 4 ÷ 168kW
  • Permitted min. air velocity: v = 1,5m/s
  • Max. permissible ambient temperature around heating components: 65°C
Close
Silencer
SL
Functions and application

Application

  • Installed in-to the AHU to ensure noise reduction downstream of the fan set

 

Type

  • SLC_STD (standardowy)
  • SLC_HEFF (wyższa skuteczność)
Construction
  • The block is fitted with silencing cartridges made of non-flammable mineral wool, 100 or 200mm thick
  • The surface of wool insert protected with veil
  • Mineral wool fulfillment is built by galvanized metal sheet frame (add. pliester coated EVO-H)
Parameters

Max. permitted air velocity: v = 4,5m/s

Accesories

Roof / Intake / Outtake

  • For outside unit is delivered roof and component of the intake and outtake
  • Components with water drainage to the side opposite from the viewing side can be additionally installed on AHU

 

Door Locks and Handles

  • Easy to use door locks and handles ensure safe unit maintenance

 

Inspection window

  • Inspection window enables to observe unit‘s internal operation. The diameter of plastic porthole is 200mm
  • The porthole could be use with darkwork (in option)

 

Internal lighting

  • Internal lighting enables to observe unit‘s internal operation through inspection window.
  • Economy light is used with switch outside the unit
Close
Empty section
ES
WH
Water heating coil
WC
Water cooling coil
EH
Electrical heater
SL
Silencer
ES
Empty section

Application

Offices
Shops & stores
Malls
Restaurants
Warehouses
Public facilities

Technical data

SIZE

VMIN

VOPT

VMAKS

EXTERNAL DIMENSIONS

SUPPLY OR EXHAUST UNIT

SUPPLY EXHAUST UNIT

W

H

HTOT

W1

H1

H1TOT

8000

500

800

1200

506

355

-

1 012

-

-

4100

500

1500

2000

661

355

-

1 322

-

-

1200

1000

2100

3500

961

355

-

1 932

-

-

Files to download

Klimor Air Designer

The web-based software offers a quick selection of products according to the specific design requirements. The software provides users with all necessary technical information.
Go to the configurator